LED with good visibility for vacuum switch display.
- To improve visibility, an LED display is adopted for the vacuum switch
- LED displays are used for set-up pressure and working pressure
- 2 points signal output type and 1point signal output with 1 analog output type is available
Selection by applications is possible. A connector wiring realize easy layout.
- Output detection accuracy is enhanced by the use of semiconductor switch
| Current consumption |
40mA or less |
| Pressure detection |
Diffused metaloxide semiconductive pressure transducer |
| Operating pressure range |
-100~0 kPa |
| Pressure setting range |
-99~0 kPa |
| Proof pressure |
0.2 MPa |
| Operating temperature range |
0~50°C (No freezing) |
| Operating humidity range |
35~85% RH (No dew condensation) |
| Power supply |
12~24VDC ±10%, Ripple (P-P) 10% or less |
| Protective structure |
IEC standard IP40 equiv. |
| Operating accuracy |
±3% F.S. or less (at Ta=25°C) |
| Response |
About 2msec |
| Indication |
0 ~ -99kPa (2-digit red LED display) |
| Sampling rate |
About 4 times/sec |
| Indication accuracy |
≦±3% F.S. ±2 digits |
| Sensor resolution |
1 digit |
- 2-point switch outputs specifications
| Factory default pressure |
-50kPa(SW1), -10kPa(SW2) |
| No. of pressure setting |
2 |
| Hysteresis |
Fixed (2% F.S. or less) |
| Switch output |
NPN open collector/30V 80mA or less (Residual voltage:0.8V or less)/PNP open collector/30V 80mA or less (Residual voltage:0.8V or less) |
| Operation indicator |
SW1:Red LED turns on when pressure is above the setting. SW2:Green LED turns on when pressure is above the setting. |
| Function |
1. MODE selector switch (ME or S1 or S2), 2. S1 setting trimmer (2/3-turn trimmer), 3. S2 setting trimmer (2/3-turn trimmer) |
- Analog output type specifications
| Factory default pressure |
-50kPa |
| No. of pressure setting |
1 |
| Hysteresis |
Variable (about 0 ~15%F.S. max.) |
| Switch output |
NPN open collector/30V 80mA or less (Residual voltage:0.8V or less)/PNP open collector/30V 80mA or less (Residual voltage:0.8V or less) |
| Operation indicator |
SW1:Red LED turns on when pressure is above the setting. SW2:Green LED turns on when pressure is above the setting. |
| Analog output voltage |
1~5V |
| Analog output Zero-point voltage |
1 ±0.1V |
| Analog output Span voltage |
4 ±0.1V |
| Analog output current |
1mA max. (load resistance min.5kΩ) |
| Analog output LIN/HYS |
±0.5% F.S. or less (at Ta=25℃) |
| Operation indicator |
Red LED turns on when pressure is above setting |
| Function |
1. MODE selector switch (ME or SW), 2. SW setting trimmer (2/3-turn trimmer), 3. HYS setting trimmer (about 0 ~15% of set value) |